Click here for Locker Group Home Page
Locker Group: Wire Mesh Specialists
Contact Sales: 01925 406614
Home Quality Policy Wire Mesh Care & Maintenance Contact Us Site Map
Locker Group: Wire Mesh Specialists
Click here for Locker Group Home Page
BS EN ISO 9001:2008 Certificate No. Q05104.
BS EN ISO 9001:2008
Certificate No Q 05104

Personnel Protection: Ladder Shield

The "Ladder" shield consists of dual skin shielding media attached to both sides of a ladder frame to provide maximum protection in areas where personnel may come into contact with the shield, such as Stair tower and Derrick areas.

Robust construction - primary radiant shielding incorporates heavy duty woven mesh for maximum heat flux reduction.

Key features

Ladder personnel shield

Request a quotation for Ladder Heatshield Personnel Protection

Ladder Shield Installations

Ladder Heatshields protecting personnel working within the turret area on FPSO KIKEH


Ladder Heatshields protecting personnel working within the turret area on FPSO KIKEH




Ladder Heatshields protecting SALTIRE drilling derrick


Ladder Heatshields protecting SALTIRE drilling derrick





Ladder Heatshields protecting processing piping in KUPE GAS onshore ‘Burn Pit’


Ladder Heatshields protecting processing piping in KUPE GAS onshore ‘Burn Pit’

 

Single Skin Ladder Shield: Wind Speed Reduction Test Results


Free Flow
Wind Speed
Speed Recorded
Behind Shield
Total Reduction
in Speed
Percentage
Reduction
Max
Deflection
(mph) (mph) (mph) (%) (mm)
55 26 29 52.7 14
60 35 25 41.7 20
65 36 29 44.6 26
70 36 34 48.6 33
75 38 37 49.3 35
80 38 42 52.5 38

Double Skin Ladder Shield: Wind Speed Reduction Test Results


Free Flow
Wind Speed
Speed Recorded
Behind Shield
Total Reduction
in Speed
Percentage
Reduction
Max
Deflection
(mph) (mph) (mph) (%) (mm)
55 15 40 72.7 18
60 18 42 70 23
65 20 45 69.2 31
70 20 50 71.4 33
75 23 52 69.3 35
80 22 58 72.5 36

Tabulated values are extracted from Test Report No. R11918

On completion of the wind speed test the shields were fully inspected and no evidence of damage was identified.

© 2016 Locker Heatshielding Ltd | Privacy Policy and Site Terms of Use