Open post
Extra-Span-Shield

Extra Span Shield

Extra Span Shield


The Extra Span type shield (formerly known as the Mini ES Shield), as a product, sits between the Mini type shield and the Ladder type shield.

The Extra Span type shield is used as a permanent solution for protect both personnel and equipment from the harsh weather conditions experienced both onshore and offshore in the oil and gas industry.

They are of a single layer construction but can be altered to provide a double layer of protection. Intended for protection of key equipment and in areas where personnel will not come into direct contact with the radiant shields.

The shield is of a single layer construction which can reduce the wind speed by up to 62% without affecting light transmission and ventilation. This can be further expanded by adding an additional layer which will reduce the wind speed by up to 72%. Protection against radiant heat is also provided.

The Extra Span Shield has been successfully tested to wind speeds in excess of 100mph.

Product Features


Key Features

  • Independently tested up to 20 kW/m2
  • Heat flux reduction in excess of 80% at 300mm behind the shield
  • Designed primarily for protection of equipment
  • Able to span large distances between supporting steelwork
  • Uses the same heavy duty radiant mesh as Ladder shields
  • All stainless steel type 316L construction
  • Lower cost and weight
  • Excellent light transmission and ventilation
  • Quick onsite installation and removal, supplied complete with all necessary A4 Stainless Steel fasteners
  • Load tested up to 8.2 kN/m2

Click to download the PDF Data Sheet for Locker Extra Span (formerly Mini ES) Heat Shield.

Key Features

  • Wind efficiency 62% (72% with additional layer)
  • Independently tested at wind speeds in excess of 100mph (87knots/h)
  • Able to span large distances between supporting steelwork
  • All stainless steel type 316L construction
  • Ideal for permanent wind and weather protection
  • Excellent light transmission and ventilation
  • Quick onsite installation and removal
  • Supplied complete with all necessary A4 Stainless Steel fasteners

Extra Span Shield: Wind Speed Reduction Test Results

Free Flow
Wind Speed
Speed Recorded
Behind Shield
Total Reduction
in Speed
Percentage
Reduction
Max
Deflection
(mph)(mph)(mph)(%)(mm)
5317366814.8
8231516233.3
8732556348.5
9435596361
9737606269.6
10138636276.5

Tabulated values are extracted from Test Report No. R11918. On completion of the wind speed test the shields were fully inspected and no evidence of damage was identified.

Click to download the PDF Data Sheet for Locker Extra Span (formerly Mini ES) Wind Shield.

Open post

Ladder Shield

Ladder Shield


The "Ladder" shield consists of dual skin shielding media attached to both sides of a ladder frame to provide maximum protection in areas where personnel may come into contact with the shield, such as Stair tower and Derrick areas.

Robust construction - primary radiant shielding incorporates heavy duty woven mesh for maximum heat flux reduction.

Key Features

  • Independently tested up to 60 kW/m2
  • Heat flux reduction in excess of 80% at 150 mm distance behind the shield.
  • Rolled Hollow section framework gives high resistance to wind buffeting.
  • All stainless steel type 316L construction.
  • Able to withstand continuous thermal cycling.
  • Excellent light transmission and ventilation.
  • Good protection against wind and snow.
  • Quick on site installation and removal, supplied complete with all necessary A4 Stainless Steel fasteners.
  • Mesh proven to reduce wind speed by over 70%
  • Load tested to 24 kN/m2

Single Skin Ladder Shield: Wind Speed Reduction Test Results

Free Flow
Wind Speed
Speed Recorded
Behind Shield
Total Reduction
in Speed
Percentage
Reduction
Max
Deflection
(mph)(mph)(mph)(%)(mm)
55262952.714
60352541.720
65362944.626
70363448.633
75383749.335
80384252.538

Double Skin Ladder Shield: Wind Speed Reduction Test Results

Free Flow
Wind Speed
Speed Recorded
Behind Shield
Total Reduction
in Speed
Percentage
Reduction
Max
Deflection
(mph)(mph)(mph)(%)(mm)
55154072.718
6018427023
65204569.231
70205071.433
75235269.335
80225872.536

Tabulated values are extracted from Test Report No. R11918

On completion of the wind speed test the shields were fully inspected and no evidence of damage was identified.

Click to download the PDF Data Sheet for Locker Ladder Heat Shield.